Specifications

PowerConnect 8132/8164/8132F/8164F/8024/8024F/M8024/M8024-k/
M6220/M6348/7024/7048/7024P/7048P/7024F/7048R/7048R-RA
Release Notes
System Firmware Version 5.1.0.1 Page 61
Summary
User Impact
Workaround
Port goes down if the
port is excluded from
native vlan with UDLD
feature enabled on it.
If the port is operating in Trunk mode and UDLD
is enabled, the port goes down if it is excluded
from the native vlan.
Include the port in native vlan.
SNMP V3 walk may fail
after “initiate failover”
command is issued.
After failover, SNMP V3 walk may fail, as MIB
browser and agent can become out of time and
stop intercommunication.
After a failover, close the browser and re-open
it. SNMPv2 works correctly.
OOB static IP entry
cannot be the same as the
DHCP assigned IP
address
After receiving an IP address from the DHCP
server, the switch gives an error and will not
allow an attempt to add a static IP address and
gateway that is the same as the DHCP IP address.
Use a different IP address than the DHCP
address given.
Release 4.2.2.3
Summary
User Impact
Workaround
Stack member units port
display is missing in
web GUI.
Wrong id for the power LED is displayed.
None
WebUI sFlow Polling
page issues.
sFlow>Sampler configuration and sFlow>Poll
Configuration don't work for ports Gig1/0/1 -
1/0/9.
None
Release 4.2.1.3
Summary
User Impact
Workaround
"show interfaces
switchport " command
shows incorrect General
Mode Tagged VLANs
value
Some general mode VLANs tagged to the
interface may not be displayed using this
command.
Use “show vlan” command to interfaces. No
other workaround.
M6220 OOB interface
unreachable after
failover
On a failover on a M6220 stack the OOB
interface may not be available.
Recovers when the master is restored.
CLI command "show ip
dhcp snooping binding"
not displaying client
information.
"show ip dhcp snooping binding" not displaying
client information. "show ip dhcp snooping
statistics" does not display correct message
counts.
None
OOB interface
configured with default
IP via Setup Wizard
though told not to do so.
The setup wizard does not honor selection to not
setup OOB IP address.
OOB IP address will need to be setup
manually.
DHCPv6 - M6220,
PC/M 8024/k - Client
Solicits do Not Seem to
Make it to the Server /
Relay
By looking at the counters, the client believes it
is sending solicits; but, the relay and the server
never see the solicitations.
None
Release 4.2.0.4
Summary
User Impact
Workaround
File modification date &
time is not getting
updated with current
time & date.
When internal files are modified, they do not get
the current time stamp.
None