The server is listed under the Host tab.
Hypervisor deployment fails for 11th generation PowerEdge blade
servers when using Active Directory
Hypervisor deployment fails on the 11th generation PowerEdge blade servers when using the Active Directory user credentials. The
11th generation PowerEdge blade servers use the Intelligent Platform Management Interface (IPMI) protocol for communication.
However, the IPMI standard is not supported for using credentials from the Active Directory setup.
As a workaround to deploy operating systems on these servers, use supported credential profiles.
RAID configuration failure for virtual disks with RAID10
RAID configuration fails when virtual disks are created with RAID level 10 for controller H200 using more than four physical disks.
RAID 10 with more than four physical disks fail.
As a workaround, use minimum number of physical disks required for that RAID level.
Configuration of RAID failure due to configuration of hot spares on
software RAID S130
RAID configuration on software RAID controller S130 fails when we try to configure RAID with more than three hot spares including
the Global Hot Spare (GHS) and DHS.
As a workaround:
Use only three hot spares (GHS and DHS) to apply on a profile.
Use the PowerEdge RAID controller (PERC) card.