Release Notes

SC2012 VMM 2012 Admin Console SP1
60424: Firmware updates are not applied on a server even when the firmware update job shows successful.
Workaround: Manually delete the completed LC jobs in iDRAC, and retry the firmware update job. For more information on deleting LC
jobs in iDRAC, see iDRAC documentation at
dell.com/support/home. This issue is highly probable on 11G servers, hence, it is
strongly recommended to clean up the jobs from the iDRAC job queue before performing a firmware update.
63442: PT-Import Server Profile-Selecting Custom Restore after refreshing the Import Profile wizard is throwing an invalid message.
Workaround: Close and relaunch the import server profile page.
62699: PT - Alignment of server identifier and hostname are not proper with the header in the create new custom group UI.
63079: PT-Discovery-Accessing the device inventory page when the discovery job is In-progress gives unknown exception error.
Workaround: Users need to ignore the exception displayed on the UI and the activity log. If the error is displayed in UI, user has to cancel
the shown error in UI and refresh the Device Inventory Page.
65464: PT-Change in DNS configuration-After you setup the appliance, if the network settings are changed, then the appliance may not
reflect the changes.
Workaround: To apply these changes restart the appliance.
31919: Applying a hardware profile with RAID configuration may fail with the following error messages: Error An unknown
exception has occurred and has been logged in the extended logs.
Error RAID configuration failed with error: An unknown exception has occurred and has been
logged in the extended logs <iDRAC IP address>
Error 0_EX_MSG
Workaround: As a workaround, do a Power Cycle System for the server and reapply the hardware configuration.
Versions Affected: 13th generation of Dell PowerEdge servers.
24881: The SCVMM console crashes while importing the DLCI for SCVMM addin, if the user has insufficient access to the folder where
the console addin is installed.
Workaround: As a workaround, install the Update Rollup 1 for SC2016 VMM, and then import the DLCI for SCVMM addin.
65482: If you are accessing local FTP using proxy credentials created by CCProxy server, then the local FTP site is not accessible.
65727: In BIOS Settings, the snoop mode attribute does not support ClusterOnDie option.
30880: The action in comparison report for OS collector component is displayed as downgrade even if it an upgrade action.
Installation Prerequisites
Managed systems are the systems that are managed using DLCI for SCVMM. Also, You can install DLCI for SCVMM on 11th generation to
13th generation of Dell PowerEdge rack and modular servers.
System requirements for managed systems:
Table 1. System requirements
PowerEdge
Servers
Lifecycle
Controller Version
Integration Dell
Remote Access
Controller Version
Dell OS Driver
Pack Version
Dell OpenManage
Deployment
Toolkit Version
Chassis Firmware
Version
13th generation 2.40.40.40 or higher 2.40.40.40 or higher 16.08.13 5.4
FX2 -1.4 or higher
M1000e -5.2 or
higher
VRTX-2.2 or higher
12th generation 2.40.40.40 or higher 2.40.40.40 or higher
For servers R220
and FM120:
16.08.13
Other supported
platforms:
15.07.07
5.4
11th generation 1.7.5.4 or higher
For Modular
servers: 2.85 or
higher
15.04.00 5.4
6 Dell Lifecycle Controller Integration Version 1.3 for Microsoft System Center Virtual Machine Manager Release Notes