Release Notes

Versions Affected:
SC2012 VMM 2012 R2 Admin Console
SC2012 VMM 2012 SP1 Admin Console
32421: Few read-only attributes of a target server are not set as read only in hardware profile.
Workaround: Edit only the applicable BIOS attributes. For more information, see the reference server's
BIOS settings.
Versions Affected:
11th Generation of PowerEdge Servers.
47941: Replicating a Hardware configuration containing RAID-0 will fail systems with S130 controller.
Workaround: The workflow will automatically create a custom RAID configuration (RAID-1) on the
selected target system.
Versions Affected:
• 13th generation of Dell PowerEdge servers with S130 controller
• SC2012 VMM 2012 Admin Console R2
• SC2012 VMM 2012 Admin Console SP1
60424: Firmware updates are not applied on a server even when the firmware update job shows
successful.
Workaround: Manually delete the completed LC jobs in iDRAC, and retry the firmware update job. For
more information on deleting LC jobs in iDRAC, see iDRAC documentation at
dell.com/support/home
.
This issue is highly probable on 11G servers, hence, it is strongly recommended to clean up the jobs from
the iDRAC job queue before performing a firmware update.
63442: PT-Import Server Profile-Selecting Custom Restore after refreshing the Import Profile wizard is
throwing an invalid message.
Workaround: Close and relaunch the import server profile page.
62699: PT - Alignment of server identifier and hostname are not proper with the header in the create
new custom group UI.
63079:PT-Discovery-Accessing the device inventory page when the discovery job is In-progress gives
unknown exception error.