Release Notes
support.microsoft.com/kb/2785682.
Do this update irrespective of the version of the update rollup that is
installed.
Versions Affected:
• SC2012 VMM 2012 Admin Console R2
• SC2012 VMM 2012 Admin Console SP1
32421: Few read-only attributes of a target server are not set as read
only in hardware profile.
Workaround: Edit only the applicable BIOS attributes. For more
information, see the reference server's BIOS settings.
Versions Affected:
•
11
th
generation of PowerEdge servers
47941: Replicating a Hardware configuration containing RAID-0 will fail
systems with S130 controller.
Workaround: The workflow will automatically create a custom RAID
configuration (RAID-1) on the selected target system.
Versions Affected:
• 13th generation of Dell PowerEdge servers with S130 controller
• SC2012 VMM 2012 R2 Admin Console and SC2012 VMM SP1 Admin Console
Bug 60425: Firmware update on two identical servers with different set of
components for each server performs the firmware update of all selected
components on both the servers, irrespective of the selection per server.
Workaround: Select the same set of components for the identical servers
and perform the firmware update.
Versions Affected:
• 12th and 13th generation of Dell PowerEdge servers with iDRAC
Enterprise License
• SC2012 VMM 2012 Admin Console R2
• SC2012 VMM 2012 Admin Console SP1
Bug: 60424 Failure of firmware update because of job queue being full.
Firmware update jobs submitted from the appliance to iDRAC fails and the
appliance main log displays the error: JobQueue Exceeds the size limit.
Delete unwanted JobID(s).
Workaround: Manually delete the completed jobs in iDRAC, and retry the
firmware update job. For more information on deleting jobs in iDRAC refer