Users Guide

Management Interface (IPMI) protocol for communication. However, the IPMI standard is not supported
for using credentials from the Active Directory setup.
As workaround: To deploy operating systems on these servers:
Use supported credential profiles.
RAID Configuration Failure for Virtual Disks with RAID10
RAID configuration fails when virtual disks are created with RAID level 10 for controller H200 using more
than four physical disks.
RAID 10 with more than four physical disks will fail.
As a workaround:
Use minimum number of physical disks required for that RAID level.
Configuration of RAID Failure due to Configuration of
Hot Spares on Software RAID S130
RAID configuration on software RAID controller S130 fails when we try to configure RAID with more than
three hot spares including the global hot spare (GHS) and DHS.
As a workaround:
Use only three hot spares (GHS and DHS) to apply on a profile.
Use PowerEdge RAID controller (PERC) card.
29