Users Guide
4. Delete the folder that contains the driver files.
Now, you can deploy operating systems.
SC2012 VMM Error 21119 While Adding Servers to Active
Directory
While adding servers to Active Directory, SC2012 VMM error 21119 is displayed. Error 21119: The
physical computer with <SMBIOS GUID> did not join Active Directory in time. The
comptuer was expected to join Active Directory using the computer name
<host.domain>.
As work-around, do the following:
1. Wait for some time to see if the server is added to the Active Directory.
2. If the server is not added to the Active Directory, then manually add the servers to the Active
Directory.
3. Add the server in to SC2012 VMM.
4. Once the server is added in to SC2012 VMM, rediscover the server in the DLCI Console.
The server is listed under the Host tab.
Connection Lost Between Appliance and Integration
Gateway
When you restart the server in which Integration Gateway is installed, connectivity is lost between
appliance and Integration Gateway. This is because the execution policy of the Integration Gateway for
the user is not active. Login to the Integration Gateway server using Integration Gateway user account to
make the execution policy active. However, after login the connection is not restored until the following
steps are completed.
To set PowerShell execution policy:
1. Set PowerShell execution policy for local system as RemoteSigned and for the Integration Gateway
Service Account
as Unrestricted.
For information on policy settings, refer the following MSDN articles:
• PowerShell Execution policy: technet.microsoft.com/en-us/library/hh847748.aspx
• PowerShell Group Policy: technet.microsoft.com/library/jj149004
2. Once the execution policy is set, restart the Integration Gateway server.
Hypervisor Deployment Fails for 11th Generation
PowerEdge Modular Servers When Using Active Directory
Hypervisor deployment fails on the 11th generation PowerEdge modular servers when using the Active
Directory user credentials. The 11th generation PowerEdge modular servers use the Intelligent Platform
28