Release Notes

49848: Inappropriate error in activity log when invalid iDRAC credentials
are selected during operating system deployment.
Workaround: During operating system deployment if you get "Read
timeout" or "Connection timeout" ensure that the Host is reachable and
you have selected a valid credential profile.
Versions Affected:
12
th
and 13
th
generation of PowerEdge servers
32421: Few read-only attributes of a target server are not set as read
only in hardware profile.
Workaround: Edit only the applicable BIOS attributes. For more
information, see the reference server's BIOS settings.
Versions Affected:
11
th
generation of PowerEdge servers
51901: On a dual controller system that contains virtual disk with a
dedicated hot spare (DHS) and the number of virtual disks in the second
controller are greater than the virtual disks present in the first controller;
while applying RAID configuration, it is observed that the second
controller’s virtual disks will have inconsistent DHS.
Workaround: Have more virtual disks created on first controller
(Integrated Controller).
Versions Affected:
12th and 13th generation of PowerEdge Servers
51902: If you update a credential profile name with an existing
credential profile name, the existing credential profile is deleted with
some unknown exception.
Workaround: Create RunAsAccount in SCVMM using the credentials of
the user who has logged in to the DLCI console in the following format
"Dell_<profileName>."
Versions Affected:
SC2012 VMM 2012 R2 Admin Console
SC2012 VMM 2012 SP1 Admin Console