Release Notes

Customization for dedicated hot spare (DHS)
Fixes
This release contains fixes for CVE-2014-7169 and CVE-2014-6271.
Important Notes
In DLCI for SC2012 VMM version 1.0.1, you cannot use hardware
profiles created for 11
th
generation and 12
th
generation PowerEdge
servers in DLCI SC2012 VMM version 1.0.
If the 11
th
and 12
th
generation of PowerEdge servers are discovered in
DLCI for SC2012 VMM version 1.0 and you have upgraded to DLCI for
SC2012 VMM version 1.0.1; After upgrade, rediscover the servers and
check for compliance.
Known Issues
42439: When you want to create a hardware profile using a reference
server that was deployed by DLCI for SC2012 VMM, you may see empty set
of disks or the message “Unable to get RAID topology.” The reason for
this is that the iDRAC system inventory is not updated.
Workaround: (Do this action only once.) Reset iDRAC in the reference
server and then recreate the hardware profile.
Versions Affected:
11
th
and 12
th
generation of Dell PowerEdge servers
38365: When an add-in is imported into the SC2012 VMM console, the
console may crash.
Workaround: See issue 5 in this knowledge base URL:
support.microsoft.com/kb/2785682
Do this update irrespective of the version of the update rollup that is
installed.
Versions Affected:
SC2012 VMM 2012 R2 Admin Console
SC2012 VMM 2012 SP1 Admin Console