Owner's Manual

72 Troubleshooting
To re-enable the
Apply
option:
a
Right-click the task sequence and select
Edit
.
b
Select
Restart in Windows PE
. In the
Description
section, type any
character and delete it so the change isn’t saved.
c
Click
OK
. This re-enables the
Apply
option.
Issue
: The System Viewer utility does not display the latest RAID
configuration.
Resolution
: When you are vieweing the RAID configuration for a system
using the System Viewer Utility, the information is cached. When you
update the RAID configuration of the same system, you must close the
System Viewer utility and re-open it to view the updated
RAID configuration.
Issue
: The Modular systems cannot use the hostname in the path to the
CIFS share but monolithic systems can use the hostname.
Resolution:
For Modular systems you must specify the IP address of
the CIFs share.
Issue:
When you are updating the systems with the latest firmware, if the
Dell Update Packages (DUPS) take longer than 50 minutes to download
over a WAN, then the update task may fail.
Resolution
: If you face this problem, then you must copy the repository
that contains the updates to the local network of the systems
you are updating.
Issue:
If you have discovered systems with DLCI for ConfigMgr version
1.0 or 1.1 and updated the firmware after upgrading to version 1.2, then
you must re-discover the systems if you change their hostname during
OS deployment.
Resolution:
Ensure that you upgrade Lifecycle Controller of the target
systems to version 1.4 or later and upgrade iDRAC on the target systems
to version 1.5 or later for monolithic systems and version 3.02 or later for
modular systems.
DLCI_UserGuide.book Page 72 Wednesday, February 2, 2011 10:49 AM