Release Notes

Known Issues
Issue 1
Description
If FlexAddress is enabled on Chassis Management Controllers, iDRAC and Lifecycle Controller do not
display the same MAC addresses.
Resolution
To view the chassis-assigned MAC address, use the iDRAC Web interface or the CMC Web interface. Go
to General-> Network Settings.
Versions Affected
All the LC2–supported Dell PowerEdge servers.
Issue 2
Description
Deployment of Windows operating system may intermittently stop with the following error message:
A required CD/DVD drive device driver is missing. If you have a driver floppy disk, CD,
DVD, or USB flash drive, please insert it now.
Resolution (only for logging on to iDRAC7 Web interface)
Restart Lifecycle Controller and retry until the operating system is successfully
deployed.
Versions/Systems Affected
Lifecycle Controller 2 version 1.4.0
Issue 3
Description
While deploying Windows Server 2008 R2 SP1 from OS Deployment of Lifecycle Controller, installation
stops with the following error:
There is no disk in the drive. Please insert a disk into drive \Device\Harddisk0\DR0.
This issue may occur due to any of the following reasons:
Virtual Media is in the attached state and a media is not mapped.
Virtual Media is in the auto-attached state and a media is not mapped.
Virtual Media being presented by the AVCT SIP and Virtual Media from iDRAC7 in the detached
state.
Due to failure to load drivers for RAID controllers on the system.
NOTE: It does not occur with Virtual Media in the detached state. It also does not occur without the SIP
and with Virtual Media in the detached from iDRAC7.
Resolution
Retry the operation.