Technical White Paper
15 NIC or CNA Card Management
This feature provides the ability to get and set the Network Interface (NIC) Card or Converged
Network Adapter (CNA) attributes that are configurable using NIC/CNA Option-ROM or NIC/CNA
UEFI HII. The attributes include functionalities for the following:
Partition and personality (CNA only)
iSCSI boot and PXE boot that are part of the NIC/CNA firmware
The ability to configure CNAs has been added to the NIC profile that extends the management
capabilities of the referencing profiles. The NICs/CNAs are modeled as views with collections
of attributes where there is a view for each partition on the controller.
The NIC/CNA Inventory has these classes and views:
1. DCIM_NICEnumeration, (see Section 15.1)
2. DCIM_NICString (see Section 15.2)
3. DCIM_NICInteger (see Section 15.3)
4. DCIM_NICView (see Section 15.4)
5. DCIM_NICCapabilities(see Section 15.5)
6. DCIM_NICStatistics(see Section 15.6)
Profile and Associated MOFS:
http://www.delltechcenter.com/page/DCIM.Library.Profile
15.1 Listing the NIC or CNA Inventory-Enumeration Class
Enumerate the
NICEnumeration
class with the following parameters and syntax:
EXAMPLE – CNA:
wsman enumerate http://schemas.dmtf.org/wbem/wscim/1/cimschema/
2/root/dcim/DCIM_NICEnumeration
-h $IPADDRESS -V -v -c dummy.cert -P 443
-u $USERNAME -p $PASSWORD -j utf-8 -y basic
OUTPUT – CNA: For SAMPLE PORT 1 / PARTITION 1 (all attributes on all partitions are enumerated)
<n1:DCIM_NICEnumeration>
<n1:AttributeName>IscsiViaDHCP</n1:AttributeName>
<n1:CurrentValue>Enabled</n1:CurrentValue>
<n1:DefaultValue xsi:nil="true"/>
<n1:FQDD>NIC.Embedded.1-1</n1:FQDD>
<n1:InstanceID>NIC.Embedded.1-1:IscsiViaDHCP</n1:InstanceID>
<n1:IsReadOnly>false</n1:IsReadOnly>
<n1:PendingValue xsi:nil="true"/>
<n1:PossibleValues>Disabled</n1:PossibleValues>
<n1:PossibleValues>Enabled</n1:PossibleValues>
</n1:DCIM_NICEnumeration>
<n1:DCIM_NICEnumeration>
<n1:AttributeName>ChapAuthEnable</n1:AttributeName>
<n1:CurrentValue>Disabled</n1:CurrentValue>