Technical White Paper
<p:ipAddress></p:ipAddress>
<p:ShareName></p:ShareName>
<p:ShareType></p:ShareType>
<p:UserName>E</p:UserName>
<p:Password></p:Password>
<p:FileName></p:FileName>
</p:ImportSystemConfigurationPreview_INPUT>
OUTPUT:
ImportSystemConfigurationPreview_OUTPUT
Job
EndpointReference
Address = http://schemas.xmlsoap.org/ws/2004/08/addressing/role/anonymous
ReferenceParameters
ResourceURI = http://schemas.dell.com/wbem/wscim/1/cim-
schema/2/DCIM_LifeCycleJob
SelectorSet
Selector: InstanceID = JID_656038536587, __cimnamespace =
root/dcim
ReturnValue = 4096
To view the job
DCIM_LifecycleJob
ElapsedTimeSinceCompletion = 1
InstanceID = JID_656038536587
JobStartTime = NA
JobStatus = Completed
JobUntilTime = NA
Message = No changes occurred. Current component configuration
matched the requested configuration.
MessageArguments = NA
MessageID = SYS069
Name = Preview Configuration
PercentComplete = 100
12.22 Remote Diagnostics
This feature will allow you to remotely run hardware diagnostics through console application or
remote scripts and collect results from tool execution.
12.22.1 Run Diagnostics
DCIM_LCService.RunePSADiagnostics: The method is used to run the diagnostics on basis of the
runmode switch and save the report in the internal storage area. The diagnostics can be run in either
express or extended mode or as a long run which encompasses all diagnostic tests.
Example:
WSMAN i RunePSADiagnostics http://schemas.dmtf.org/wbem/wscim/1/cim-
schema/2/root/dcim/DCIM_LCService?SystemCreationClassName=DCIM_ComputerSystem
+CreationClassName=DCIM_LCService+SystemName=DCIM:ComputerSystem+Name=DCIM:LC