Practices Guide
Lifecycle Controller Integration―Best Practices Specification
79
Applies to: LC2+
Prerequisites for script: none
Script: GetEventFilterProfile.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any
other WSMAN commands.
GetRemoteServicesAPIStatus():
B) GetLCRegisteredProfiles(): ENUMERATE the DCIM_LCRegisteredProfile class to view all
registered profiles. See section 2.2 for a definition of
ENUMERATE .
C) Search for “RegisteredName=Event Filter” and note its instanceID to use in step D)
D) GetLCRegisteredProfile(): GET the DCIM_LCRegisteredProfile instance using the
InstanceID from C). See Section 2.3 for a definition of
GET.
Results for the InstanceID of DCIM:EventFilter:1.0.0 shown below. If no instance is returned,
the profile is not supported.
DCIM_LCRegisteredProfile
AdvertiseTypeDescriptions = WS-Identify
AdvertiseTypeDescriptions = Interop Namespace
AdvertiseTypes = 1
AdvertiseTypes = 1
InstanceID = DCIM:EventFilter:1.0.0
OtherRegisteredOrganization = DCIM
ProfileRequireLicense = Remote Firmware Configuration
ProfileRequireLicenseStatus = LICENSED
RegisteredName = Event Filter
RegisteredOrganization = 1
RegisteredVersion = 1.0.0
8.2 Get Event Filter Configuration Service Views
Enumerate the DCIM_EFConfigurationService class to view all available instances of the class.
Applies to: LC2+
Prerequisites for script: none
Script: GetEFConfigurationServiceViews.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any
other WSMAN commands.
GetRemoteServicesAPIStatus():
B) GetEFConfigurationServiceViews(): ENUMERATE the DCIM_EFConfigurationService class
to view all instances. See section 2.2 for a definition of
ENUMERATE .
The instance information will be returned.