Practices Guide

Lifecycle Controller IntegrationBest Practices Specification
25
Recommendation:
Change the Telnet attributes prior to setting the SerialRedirection.Enable attribute. Or, if using
input XML, have the Telnet attributes before the SerialRedirection.Enable attribute.
3.7 Never Unplug Hardware During Updates
Users should not unplug any hardware during critical remote enablement (RE) updates. This may result
in unexpected behaviors.
As an example, unplugging a USB key during critical updates may cause a Red Screen of Death (RSOD).
3.8 Express Versus Enterprise iDRACs
There are four levels of iDRAC licensing as follows:
1) Basic
2) Express (Monolithic)
3) Express for blades(Modular)
4) Enterprise
One method of determining the level on a system is to perform an enumeration of the
DCIM_iDRACCardView class. Example results are shown for reference.
Monolithic:
DCIM_iDRACCardView
FQDD = iDRAC.Embedded.1-1
FirmwareVersion = 1.00.00
GUID = 3132334f-c0b7-3480-3510-00364c4c454
IPMIVersion = 2.0
InstanceID = iDRAC.Embedded.1-1#IDRACinfo
LANEnabledState = 1
LastSystemInventoryTime = 20120302092309.000000+000
LastUpdateTime = 20120305233206.000000+000
Model = Enterprise
PermanentMACAddress = 78:2b:cb:54:54:11
ProductDescription = This system component provides a complete set of remote management
functions
for Dell PowerEdge servers
SOLEnabledState = 1
Modular:
DCIM_iDRACCardView
FQDD = iDRAC.Embedded.1-1