B) GetSensorViews(): ENUMERATE the CIM_Sensor class to view all instances. Check the
instance of either DCIM_PSNumericSensor and DCIM_NumericSensor to see if there are any
settable thresholds
C) SetSensorThreshold(): SET the DCIM_PSNumericSensor instance for temperature. Set
the LowerThresholdNonCritical and UpperThresholdNonCritical values.
24 Base Server and Physical Asset Profile Use Cases
24.1 Discovery of Base Server and Physical Asset Profile Support
There is not an LC registered Base Server and Physical Asset Profile prior to LC2.0.
Use the following procedure below to confirm the existence of the Base Server and Physical
Asset profile support in LC2.0+.
Applies to: LC2+
Prerequisites for script: none
Script: GetBaseServerAndPhysicalAssetProfile.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any
other WSMAN commands.
GetRemoteServicesAPIStatus():
B) GetLCRegisteredProfiles(): ENUMERATE the DCIM_LCRegisteredProfile class to view all
registered profiles. See section 2.2 for a definition of
ENUMERATE .
C) Search for “RegisteredName= Base Server and Physical Asset” and note its instanceID to use
in step D)
D) GetLCRegisteredProfile(): GET the DCIM_LCRegisteredProfile instance using the
InstanceID from C). See Section 2.3 for a definition of
GET.
Results for the InstanceID of DCIM:BaseServerandPhysicalAsset:1.0.0 shown below. If no
instance is returned, the profile is not supported.
DCIM_LCRegisteredProfile
AdvertiseTypeDescriptions = WS-Identify
AdvertiseTypeDescriptions = Interop Namespace
AdvertiseTypes = 1
AdvertiseTypes = 1
InstanceID = DCIM:BaseServerandPhysicalAsset:1.0.0
OtherRegisteredOrganization = DCIM
ProfileRequireLicense
ProfileRequireLicenseStatus
RegisteredName = Base Server and Physical Asset
RegisteredOrganization = 1
RegisteredVersion = 1.0.0