Release Notes
− For SLES 11 SP2:
A prompt appears for the Super user password in the operating system console. Provide the root
password and proceed with the graceful shutdown or firmware/BIOS update.
− For Windows OS in screen lock state:
Graceful shutdown does not happen because, Windows operating system has a policy setting to
disable shutdown while in locked state. Make sure that this policy is enabled.
If it is not enabled, then it proceeds with ungraceful shutdown. This is equivalent to losing power.
After the server resets, multiple options are displayed to start Windows. Select Start Windows
Normally and then check the System Event Log file. You can see that an event is logged in for the
ungraceful shutdown.
•
In the iDRAC Web interface >
Overview
>
Server
>
Lifecycle Log
page, when the filter criteria
results in nothing found, the
Log Results
section does not display any user-friendly information
and it is blank instead.
•
VNC disconnects after host reboot on Wyse PocketCloud,
•
Encrypted VNC does not work through Real VNC client.
•
VNC does not work through mobile when encryption is enabled.
•
OS to iDRAC communication through the USB NIC interface is not supported on RHEV – H
(hypervisor) system.
•
OS to iDRAC pass-through feature does not work when the host operating system is Linux.
•
iDRAC Virtual NIC driver is not loaded when Windows 2008 SP2 (64 bit) installation has
completed.
•
When Virtual Console is in Lifecycle Controller, if
Next Boot
is set to
BIOS Setup
, rebooting the
system boots to Lifecycle Controller instead of BIOS Setup.
LC2-RS - Fixes
BITS104701: PCIe SSD configuration should be blocked through Remote Services
LC2-RS - Important Notes
If the iDRAC7 version is 1.50.50, Lifecycle Controller version must to be updated to 1.3.0.x.
LC2-RS - Known Issues
Issue 1:
Description
Lifecycle Controller may not perform the required operation correctly if incompatible iDRAC firmware is
used.
Resolution
Update the Lifecycle Controller version to 1.3.0.x if the iDRAC7 version is 1.50.50.
Versions/Systems Affected
All LC2-RS supported Dell PowerEdge systems.