Release Notes
Issue 46:
Description
Full export of Lifecycle Controller logs in Mac OS through Safari browser generates Log.xml file instead
of Log.xml.gz file and the Log.xml contains partial content.
Resolution
1. Open Safari in Mac.
2. Go to Safari > Preferences > General.
3. Clear the Open 'safe' files after downloading option.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 47:
Description
In some scenarios, typically when a PCIe SSD is removed from a server slot and a different PCIe SSD is
inserted within a span of 5-10 seconds into the same slot, the server fan speeds may not get optimally
configured to accommodate the thermal profile or tier of the inserted PCIe SSD.
Resolution
Power cycle the server.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and PCIe SSDs.
Issue 48:
Description
On servers with Windows 2008 SP2 64-bit operating system, the iDRAC Virtual NIC USB Device is not
discovered automatically (or enabled). The iDRAC Virtual NIC USB Device appears under unknown
devices with yellow bang (or warning symbol).
Resolution
See steps recommended by Microsoft to manually update the RNDIS driver for this device.
Versions/Systems Affected
All Dell PowerEdge Systems with iDRAC7.
Issue 49:
Description
If the system with Linux operating system is stand alone or connected to a network hub, the
communication to iDRAC through the OS to iDRAC pass-through channel for LOM pass-through mode
does not work in the following scenarios:
1. For systems shipped from factory, initially the iDRAC network is in dedicated mode and the OS to iDRAC
pass-through feature for LOM pass-through mode is disabled. The network cable is installed at LAN1. The
host and the iDRAC IPs are configured for static IP addresses in the same subnet. Switch the iDRAC
network from dedicated to shared mode, enable OS to iDRAC pass-through and set the pass-through
mode to LOM.
2. When LAN1 is connected to a switch:
a.
Both iDRAC and the host IPs are configured for static IP addresses in the same subnet.
b.
Either iDRAC or the host IP is configured for static IP address and the other one
received the IP through DHCP.
c.
iDRAC and host both receive the IP through DHCP.