Issue 15:
Description
When a power reset is performed, the Virtual Console Viewer menu options (except File -> Exit and
Help options) are grayed-out or inaccessible. The 'Link interrupted' message appears at the bottom of
Virtual Console Viewer.
Resolution
Due to a temporary network outage, the Virtual Console Viewer menu options are not accessible. The
"Link interrupted" message is displayed to indicate that an outage has occurred. This is a temporary
problem and the menu options are available when the network is restored.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 16:
Description
iDRAC7 Web interface does not respond when using Internet Explorer.
Resolution
Close all Internet Explorer sessions and open it again to access iDRAC7 Web interface.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 17:
Description
When a driver pack DUP update is performed, the following message is recorded in the Lifecycle log after
the driver pack update entry.
RAC0400: iDRAC memory low iDRAC is running low on memory. System performance may be degraded.
Recommended Action: No response action is required.
Resolution
No workaround is required. This is a normal condition when the memory is lower than the threshold for
around 30 seconds and returns to normal after the driver pack update finishes.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 18:
Description
Resetting iDRAC7 to default values action may take between four to six minutes to complete.
Resolution:
Wait for iDRAC7 to reboot before performing any other action.
Versions/Systems Affected