Release Notes

Issue 5
Description
For an Intel(R) Ethernet X520 10GbE Dual Port KX4-KR Mezzanine card, after the firmware is downgraded from version
14.0.12 to version 13.5.6, the View Current Versions page displays the firmware version for the card as 5.6 instead of 13.5.6.
Resolution
Update the firmware by running the Update Package through the operating system.
Versions/Systems Affected
Lifecycle Controller 2 version 1.1.1
Limitations
Limitation 1
Description
The following characters are supported for 'User Name' and 'Password':
Digits (0
9)
Alphanumeric (a
z, A
Z)
Hyphen (-)
Note: For 'Domain Name', a period (.) is allowed. For example, 'x123.com'.
Versions/Systems Affected
All
Limitation 2
Description
While updating an iDRAC firmware by using a tool other than Lifecycle Controller, Lifecycle Controller must not be open, or
running; because, it results in an unknown behavior. Use Lifecycle Controller after the firmware is successfully updated.
Versions/Systems Affected
All
Limitation 3
Description
If the iDRAC firmware update is interrupted for any reason, wait for 30 minutes before attempting another firmware update.
Versions/Systems Affected
All