29.3 Inventory of software in system
Use the following procedure below to list the inventory of all software in the system.
Applies to: LC1.4.0+
Prerequisites for script: none
Script: GetSoftwareInventoryViews.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any
other WSMAN commands. The GetRSStatus() method or the GetRemoteServicesAPIStatus()
method may be used depending on the version of the LC Management registered profile.
B) GetSoftwareIdentities(): ENUMERATE the DCIM_SoftwareIdentity class to view all
instances. See section 2.2 for a definition of ENUMERATE .
The instance information of all available software will be returned.
29.4 Get the installed BIOS firmware inventory
Use the following procedure to get the BIOS installed software instance. The URI for getting
particular instance information is deterministic (i.e the InstanceID will be unique for each
instance).
Applies to: LC1.4.0+
Prerequisites for script: none
Script: GetInstalledBIOSView.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any
other WSMAN commands. The GetRSStatus() method or the GetRemoteServicesAPIStatus()
method may be used depending on the version of the LC Management registered profile.
B) GetSoftwareIdentities(): ENUMERATE the DCIM_SoftwareIdentity class to view all
instances. See section 2.2 for a definition of ENUMERATE .