White Papers

LC Integration Best Practices Specification
120
Use the following procedure below to confirm the existence of License Management profile
support.
Applies to: LC2+
Prerequisites for script: none
Script: GetLicenseManagementProfile.win
A) The Lifecycle Controller remote service must be in a “ready” state before executing any
other WSMAN commands.
GetRemoteServicesAPIStatus():
B) GetLCRegisteredProfiles(): ENUMERATE the DCIM_LCRegisteredProfile class to view all
registered profiles. See section 2.2 for a definition of ENUMERATE .
C) Search for “RegisteredName= License Management” and note its instanceID to use in step
D)
D) GetLCRegisteredProfile(): GET the DCIM_LCRegisteredProfile instance using the
InstanceID from C). See Section 2.3 for a definition of GET.
Results for the InstanceID of DCIM:LicenseManagement:1.0.0 shown below. If no instance is
returned, the profile is not supported.
DCIM_LCRegisteredProfile
AdvertiseTypeDescriptions = WS-Identify
AdvertiseTypeDescriptions = Interop Namespace
AdvertiseTypes = 1
AdvertiseTypes = 1
InstanceID = DCIM:LicenseManagement:1.0.0
OtherRegisteredOrganization = DCIM
ProfileRequireLicense = Licensing Management
ProfileRequireLicenseStatus = LICENSED
RegisteredName = License Management
RegisteredOrganization = 1
RegisteredVersion = 1.0.0
27 Power Supply Profile Use Cases
27.1 Discovery of Power Supply profile support
Use the following procedure below to confirm the existence of Power Supply profile support.
Applies to: LC1.5.0+
Prerequisites for script: none