Users Guide

Error Message Resolution
Invalid USB and Network Share Folder
Location
Provide the valid folder location.
The Update Package is not supported for
this System
Ensure that the update package is supported on the system.
Invalid Update Package Ensure that the update package is not corrupt or tampered.
The Server Profile backup operation that
was initiated from Lifecycle Controller
completed with errors.
The RAC log contains the names of the components that failed during
backup. Verify the firmware information and retry.
Failed to copy the backup server profile to
the SRVCNF partition on the vFlash SD
card.
Make sure that the vFlash SD card is installed, initialized, and enabled.
The restore operation initiated from
Lifecycle Controller has completed with
errors. For more information, refer RAC log.
The RAC log contains the names of the components that failed during
restore. Verify the firmware information and retry.
Initiating restore failed. Retry restore
operation after sometime.
Perform AC power cycle and retry.
Cannot complete the operation as the
vFlash SD Card is not present. Insert the
vFlash SD card and retry.
Install the vFlash SD card and retry the operation.
Upload the required license to enable vFlash SD card and retry.
There is not enough space on vFlash to
perform this operation. It needs at least 384
MB of available space.
Delete the existing partitions and unwanted files, so that 384 MB of free
space is available.
This operation cannot be completed
because one or more partitions are locked.
Unlock the partition and retry.
Use the iDRAC vFLash SD card wizard to unlock the partitions, and retry
the operation.
This operation cannot be completed
because one or more partitions are in use.
Retry after waiting a few minutes.
Complete the other operations that are using the partitions, and retry the
operation.
This operation cannot be completed
because the SD Card is not present. Insert
the SD card and retry.
Make sure the card is present and the system has the required license
uploaded to enable vFlash feature.
The Server Profile backup operation that
was initiated from Lifecycle Controller
could not be completed. Check iDRAC RAC
logs for more information.
The RAC log contains the names of the components that failed during
backup. Verify the firmware information and retry.
Rekey failed. Retry. Make sure that the latest version of the storage controller firmware is
installed.
Failed to encrypt unsecure virtual disks. Make sure that the latest version of the storage controller firmware is
installed.
Repairing Lifecycle Controller
If the message Lifecycle Controller update required appears during power-on self-test (POST), the
embedded device that stores Lifecycle Controller may contain corrupted data. To resolve the issue, you must first
attempt to update Lifecycle Controller by executing Lifecycle Controller Dell Update Package (DUP). See the
Dell Update
Packages User’s Guide
available at support.dell.com/manuals for more information. If running the DUP does not solve
the problem, use Lifecycle Controller repair package: