Release Notes
If invalid credentials are used for the maximum login attempts, the IP is blocked for the duration of the IP Blocking
Penalty Time and a message is not displayed.
If Internet Explorer (IE) 64-bit browser is used to log in to iDRAC7 Web interface and when viewing the power
usage graph, the X and Y axis labels appear too small to read. This is a known limitation for IE 64-bit only. The
labels appear correctly in IE 32-bit browser.
On Linux management stations, if Firefox is launched from the root user, a USB key is mapped in Virtual Media
successfully. If Firefox is launched from any user other than the root user, a USB key is not shown for mapping
because the user must have root privileges to access all the low-level drives.
Alert notification for battery events does not work.
Operating system information on the System Summary page does not display after rebooting iDRAC7 until the
operating system is rebooted.
iDRAC7 users with user names containing a semi-colon (;) cannot log in to iDRAC7 through SSH.
In the iDRAC7 Web interface, the power consumption sensor reading may have a rounding error of up to 13 Watts
depending on the actual power reading. This is an IPMI limitation. The power cap, power graphs, cumulative
power, and peak power are not affected by this inaccuracy. However, the power values shown in the power graphs
are average values over a period of time and should not be used to calculate instantaneous power.
In the iDRAC7 Web interface, the power consumption sensor reading may have a rounding error of up to 13 Watts
depending on the actual power reading. This is an IPMI limitation. The power cap, power graphs, cumulative
power, and peak power are not affected by this inaccuracy. However, the power values shown in the power graphs
are average values over a period of time and should not be used to calculate instantaneous power.
In the iDRAC7 Web interface, while viewing the CPU details under
Overview
>
Hardware
, the CPU status is
displayed with a warning icon for a CPU that is absent and the status is blank.
iDRAC7 - Open Issues and Resolutions
Fixed Issues/def
Issue 1
Description
In Chinese locale on Windows operating system, while launching the Virtual Console using Java plug-in, occasionally you may
see a Java compilation error.
Resolution
1.
Open the Java control panel.
2.
Go to
General
>
Network Settings
.
3.
Select
Direct Connection
and click
OK
.
Versions Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 2
Description
Known iDRAC7 IPv6 limitations:
Email alerts are not sent if the iDRAC7 DNS Domain Name is not specified when using IPv6.
Network File Share (NFS) mounting does not work with IPv6. This applies to features such as connecting a remote
file share or exporting the Lifecycle Controller log to a network shared location.