System Characterization must be enabled to correctly run the firmware update during system power on after a
Power Supply Unit (PSU) replacement. If System Characterization is not enabled, the firmware update runs after
the next host reboot.
If the system is shut down or left in the shutdown state while a job is in progress, the job cannot progress further.
Delete the job and run it again.
LC2-RS - Open Issues and Resolutions
Issue 1
Description
When the status of the DUP update is checked using the WS-MAN query for the job InstanceID of the DCIM_LifecycleJob, the
'Percentage Complete' parameter value displays 'NA' even though the job is in-progress or complete.
Versions/Systems Affected
All LC2-RS supported Dell PowerEdge systems.
Issue 2
Description
After running a BIOS or NIC job, if you pause (by pressing Pause key on keyboard) during POST and run another BIOS or NIC
job, it fails.
Versions/Systems Affected
All LC2-RS supported Dell PowerEdge systems.
Issue 3
Description
While performing platform update using the NFS share option, if the NFS service is stopped or network connection to the
NFS share is lost while the job is in a downloading state, the job does not fail and continues to stay in a downloading state.
Resolution
To change the job status to:
Downloaded successfully - Restart the NFS service or re-establish the network connection.
Failed - Reset iDRAC7.
Versions/Systems Affected
All LC2-RS supported Dell PowerEdge systems.