Release Notes

Issue 24
Description
After performing storage operations on PERC through Option-ROM (CTRL-R) or before a system reset (warm boot), the
corresponding events are not recorded in Lifecycle log. SNMP traps are generated and the corresponding inventory changes
are not reflected in the iDRAC7 Web interface or RACADM.
Resolution
To update the storage inventory, perform a server power cycle (cold boot).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 25
Description
If a NIC card, with partitioning enabled, is replaced with a similar type of card, without partitioning enabled, the
configurations from the previous card are not applied to the new card.
Resolution
After the previous card is replaced with a new card and the system is powered on, go to Option
ROM (CTRL-R)
and enable
partitioning. Save, exit, and reboot the system.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 26
Description
When using DownloadServerPublicKey or DownloadClientCerts commands in WSMAN, the invocation may fail when the
iDRAC7 system is not ready to service these operations.
This might happen when host system is in a POST stage.
Resolution
Retry the command later or wait until host system past POST stage and retry the same command again.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.