Release Notes
Issue 20
Description
In the
iDRAC7
Web interface
>
Overview
>
Server
>
Power/Thermal
>
Power Monitoring
tab >
Power
section, the Power
Unit selector only changes the unit of measure. Due to the oscillating nature of power, the present reading cannot be
displayed as units for Current (Amps).
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 21
Description
On all Intel NICs, each port cannot be assigned different iSCSI initiator name (by assigning the value for IscsiInitiatorName).
If the name is changed for one port, the same change is applied to all ports.
Resolution
None.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 22
Description
When virtual world wide name and virtual world wide port name attributes on a NIC partition are set using the WS-MAN
interface, the new values are not updated in the iDRAC7 Web interface or when racadm getsysinfo is run.
Resolution
Use WS-MAN interface to obtain the updated values for those attributes.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 23
Description
After a virtual disk is renamed using OpenManage Server Administrator or other applications, the new name is not displayed
in the iDRAC7 Web interface or RACADM.
Resolution
For the specific virtual disk, change other attributes such as read policy, write policy and the modified name of the virtual
disk is displayed.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.