Release Notes
Issue 8
Description
When enclosures connected in the redundant path are re-wired (connections are switched) to result in a non-redundant
path, the reported connected port value of the enclosures may not be accurate.
Resolution
Power cycle the server.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 9
Description
When a storage enclosure is disconnected or accidentally removed, the corresponding status of its components (that is, EMM,
PSU, fan, and temperature sensors) are reported as critical.
Resolution
If the storage enclosure is disconnected accidentally, reconnect it to get back to normal state. If it is intentional, perform
DRAC7 reboot or server power cycle to remove the enclosure entries from the consoles.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 10
Description
Logging in to iDRAC7 Web interface fails with the error message 'RAC0218: The maximum number of user sessions is reached'.
When the temporary folder used by iDRAC7 components is full, it is possible that authentication fails and this error is
displayed.
Resolution
Power cycle iDRAC7 to clear the temporary space.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.