Release Notes

Issue 5
Description
If you are using Linux management station, you may have problems moving or resizing the Virtual Console when
Pass all
keystrokes to server
is enabled. This is a limitation of X-Windows.
Resolution
Either disable
Pass all keystrokes to server
if the problem occurs or click in the workspace outside the Virtual Console
window so that the console loses focus. Now, reposition and resize the Virtual Console. The keystroke option is restored if it
was in use and temporarily disabled.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge systems.
Issue 6
Description
vFlash functionality remains enabled after unpreserved firmware update.
If vFlash functionality is enabled and a firmware update is performed without preserving the configuration (preserve
configuration unchecked), the vFlash enabled option remains selected. This is a known behavior.
Resolution
You must manually enable or disable the vFlash functionality after the firmware update as required. To do this, select or
clear the
vFlash Enabled
option in the iDRAC7 Web interface, or use RACADM or WinRM remote service commands.
Versions/Systems Affected
All iDRAC7 supported Dell PowerEdge(TM) systems.
Issue 7
Description
In some scenarios, typically for state change events occurring within a span of few seconds, the sequence of events
reported in the Lifecycle Log (or corresponding SNMP traps) for storage devices may not exactly match the sequence in
which they occurred.
Resolution
The current state or attribute of the storage device can be checked in any of the iDRAC7 interfaces (example, iDRAC7 Web
interface, RACADM and so on).
Versions/Systems Affected
All Dell PowerEdge(TM) systems with iDRAC7 and out-of-band enabled PERC storage controllers.