Users Guide
Rolling Back to Previous Versions
Use the InstallFromSoftwareIdentity() method to reinstall from previous versions of firmware that is stored in the
Lifecycle Controller. Instead of downloading the DUP, the InstallFromSoftwareIdentity() creates a job and returns the job
ID.
NOTE: Lifecycle Controller, Diagnostics, and Driver Pack updates cannot be rolled back.
Using Remote Firmware Inventory
The remote firmware inventory feature retrieves an inventory of the currently installed firmware on various devices in
the managed system. It also retrieves the versions available for rollback (N and N-1 versions).
The remote firmware inventory feature allows you to run an inventory independent of the system state and the operating
system state. You can get a list of firmware for devices that are installed, and also the firmware that is available for
rollback and reinstallation.
NOTE: The iDRAC user credentials that are used for the WS-Management request authentication require login
privileges to request firmware and embedded software inventory. However, it is not restricted to administrators.
Supported Devices
Remote instant firmware inventory is supported for these devices and components:
• iDRAC7
• Storage controllers (RAID Series 7 and 8)
• NICs and LOMs (Broadcom, Intel, and QLogic)
• Power supplies
• BIOS
• OS Driver Pack
• Lifecycle Controller
• Diagnostics
• Complex programmable logic device (CPLD)
• Physical Disks
• Enclosures
The instant firmware inventory class provides firmware inventory information on:
• Firmware installed on the supported devices.
• Firmware versions available for installation for each device.
Retrieving Firmware Inventory
The Dell Software Inventory profile defines the Dell CIM data model extensions that represent the installed and available
to be installed versions of firmware and embedded software on the server. The firmware inventory can be accessed
using the WS-Management Web services protocol.
NOTE: There may be DCIM_SoftwareIdentity instances for hardware that were previously installed and
then removed. Such instances are put plisted in the inventory as available if CSIOR is not performed.
To retrieve the firmware inventory using Windows WS-Management: