User's Manual

Description
The maximum number of time (in seconds) of line idle time before the line is disconnected. (Type hexadecimal values.)
cfgSerialConsoleShellType (Read/Write)
Default
Default 2
Legal Values
1 = VT100 block screen interface, has limited command function compared to type 2.
2 =UNIX®-style command line data stream interface.
Description
Sets the serial console shell type. (Type hexadecimal values.)
cfgSerialConsoleNoAuth (Read/Write)
Description
Allows you to disable authentication on the serial shell.
Default
0
Legal Values
0 Login prompt is Enabled on the serial shell.
1 Login prompt is Disabled on serial shell.
cfgSerialConsoleCommand (Read/Write)
Description
The serial command runs after login at the start of a session and allows you to set up a command such as connect com2 that autoruns when a session
begins.
Default
Empty string (no command).
Example
connect com2
NOTE: To modify this property, you must have Configure DRAC 4 permission.
NOTE: To modify this property, you must have Configure DRAC 4 permission.
NOTE: To modify this property, you must have Configure DRAC 4 permission.