User's Manual
cfgSessionManagement
This group contains parameters to configure the number of sessions that can connect to the
DRAC 4.
One instance of the group is allowed. All objects in this group require a DRAC 4 reset before they become active. The following subsections describe the
objects in this group.
cfgSsnMgtMaxSessions (Read/Write)
Legal Values
0x1 through 0x4
Default
0x4
Description
The maximum number of simultaneous sessions that are allowed at one time from the DRAC 4 Web-based remote access interface. (Type hexadecimal values.)
cfgSsnMgtMaxSessionsPerUser (Read/Write)
Legal Values
0x1 through 0x4
Default
0x4
Description
The maximum number of simultaneous sessions allowed per user. (Type hexadecimal values.)
cfgSerial
This group contains configuration parameters for the system external serial port.
One instance of the group is allowed. The following subsections describe the objects in this group.
cfgSerialBaudRate (Read/Write)
Legal Values
9600, 28800, 57600, 115200
NOTE: To modify this property, you must have Configure DRAC 4 permission.
NOTE: To modify this property, you must have Configure DRAC 4 permission.
NOTE: To modify this property, you must have Configure DRAC 4 permission.
NOTE: For best results redirecting BIOS System Setup screens, Dell recommends using 115200.