Release Notes

Issue 22
Description
When virtual world wide name and virtual world wide port name attributes on a NIC partition are set using the WS-MAN
interface, the new values are not updated in the iDRAC7 Web interface or when racadm getsysinfo is run.
Resolution
Use WS-MAN interface to obtain the updated values for those attributes.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7.
Issue 23
Description
After a virtual disk is renamed using OpenManage Server Administrator or other applications, the new name is not displayed
in the iDRAC7 Web interface or RACADM.
Resolution
For the specific virtual disk, change other attributes such as read policy, write policy and the modified name of the virtual
disk is displayed.
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 24
Description
After performing storage operations on PERC through Option-ROM (CTRL-R) or before a system reset (warm boot), the
corresponding events are not recorded in Lifecycle log. SNMP traps are generated and the corresponding inventory changes
are not reflected in the iDRAC7 Web interface or RACADM.
Resolution
To update the storage inventory, perform a server power cycle (cold boot).
Versions/Systems Affected
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.