Release Notes
Issue 19 
Description 
While deploying Windows 2008 R2 SP1 from Lifecycle Controller GUI > OS Deployment, installation terminates with the 
following error: 
 There is no disk in the drive. Please insert a disk into drive \Device\Harddisk0\DR0. 
 This issue may occur due to any of the following reasons 
•
Virtual Media is in the attached state with no media mapped. 
•
Virtual Media is in the auto attached state with media mapped.  
•
Virtual Media being presented by the AVCT SIP and Virtual Media from iDRAC7 in the detached state.  
•
The underlying cause may be due to failure to load drivers for RAID controllers on the system. 
NOTE
: It does not happen with Virtual Media in the detached state. It also does not happen without the SIP and with 
Virtual Media in the detached state from iDRAC7. 
Resolution 
Retry the operation. 
Versions/Systems Affected  
All Dell PowerEdge systems with iDRAC7.
Issue 20 
Description 
In the 
iDRAC7
Web interface
 > 
Overview
 > 
Server
 > 
Power/Thermal
 > 
Power Monitoring
 tab > 
Power
 section, the Power 
Unit selector only changes the unit of measure. Due to the oscillating nature of power, the present reading cannot be 
displayed as units for Current (Amps). 
Resolution 
None. 
Versions/Systems Affected  
All Dell PowerEdge systems with iDRAC7. 
Issue 21 
Description 
On all Intel NICs, each port cannot be assigned different iSCSI initiator name (by assigning the value for IscsiInitiatorName). 
If the name is changed for one port, the same change is applied to all ports. 
Resolution 
None. 
Versions/Systems Affected  
All Dell PowerEdge systems with iDRAC7. 