Release Notes
Resolution 
You must manually enable or disable the vFlash functionality after the firmware update as required. To do this, select or 
clear the 
vFlash Enabled
 option in the iDRAC7 Web interface, or use RACADM or WinRM remote service commands. 
Versions/Systems Affected  
All iDRAC7 supported Dell PowerEdge(TM) systems.
Issue 7 
Description 
In some scenarios, typically for state change events occurring within a span of few seconds, the sequence of events 
reported in the Lifecycle Log (or corresponding SNMP traps/email alerts) for storage devices may not exactly match the 
sequence in which they occurred. 
Resolution 
The current state or attribute of the storage device can be checked in any of the iDRAC7 interfaces (example, iDRAC7 Web 
interface, RACADM and so on). 
Versions/Systems Affected  
All Dell PowerEdge(TM) systems with iDRAC7 and out-of-band enabled PERC storage controllers.
Issue 8 
Description 
When enclosures connected in the redundant path are re-wired (connections are switched) to result in a non-redundant 
path, the reported connected port value of the enclosures may not be accurate. 
Resolution 
Power cycle the server. 
Versions/Systems Affected  
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers. 
Issue 9 
Description 
When a storage enclosure is disconnected or accidentally removed, the corresponding status of its components (that is, EMM, 
PSU, fan, and temperature sensors) are reported as critical. 
Resolution 
If the storage enclosure is disconnected accidentally, reconnect it to get back to normal state. If it is intentional, perform 
DRAC7 reboot or server power cycle to remove the enclosure entries from the consoles. 
Versions/Systems Affected  
All Dell PowerEdge systems with iDRAC7 and out-of-band enabled PERC storage controllers.










