White Papers
Dellâ„¢ Lifecycle Controller 2 Web Services Interface Guide for Windows  Version: 2.1.0 
223 
 PossibleValues = Disabled 
 PossibleValues = Enabled 
 PossibleValuesDescription 
. 
. 
23.6  Changing the FC Attributes-SetAttribute() 
The SetAttribute() method can be used to change the FC configuration. 
Invoke SetAttribute() with the following parameters and syntax: 
TARGET: Obtained from the InstanceID field 
AttributeName: Obtained from the AttributeName field 
AttributeValue: Obtained from the PossibleValues field 
EXAMPLE: 
winrm i SetAttribute http://schemas.dmtf.org/wbem/wscim/1/cim-
schema/2/root/dcim/DCIM_FCService 
?SystemCreationClassName=DCIM_ComputerSystem 
+CreationClassName=DCIM_FCService 
+SystemName=DCIM:ComputerSystem 
+Name=DCIM:FCService  
-u:[USER] -p:[PASSWORD]  
-r:https://[IPADDRESS]/wsman -SkipCNcheck -SkipCAcheck  
-encoding:utf-8 -a:basic -file:SetAttribute_FC.xml 
The input file SetAttribute_FC.xml is shown below: 
<p:SetAttribute_INPUT xmlns:p="http://schemas.dmtf.org/wbem/wscim/1/cim-
schema/2/root/dcim/DCIM_FCService"> 
 <p:Target>FC.Slot.2-2</p:Target>  
 <p:AttributeName>PortSpeed</p:AttributeName> 
 <p:AttributeValue>4G</p:AttributeValue> 
</p:SetAttribute_INPUT>  
OUTPUT: 
SetAttribute_OUTPUT 
 Message = The command was successful 
 MessageID = FC001 
 RebootRequired = Yes 
 ReturnValue = 0 
 SetResult = Set PendingValue 
23.7  Applying the Pending Values for FC-CreateTargetedConfigJob() 
This method is called to apply the pending values created by the SetAttribute() and  SetAttributes() 
methods. The system will automatically reboot depending on the ScheduledStartTime selected. Using 