White Papers
Dellâ„¢ Lifecycle Controller 2 Web Services Interface Guide for Windows  Version: 2.1.0 
188 
OUTPUT: 
DCIM_BIOSString 
 AttributeName = OneTimeCustomBootStr 
 CurrentValue = null 
 DefaultValue = null 
 FQDD = BIOS.Setup.1-1 
 InstanceID = BIOS.Setup.1-1:OneTimeCustomBootStr 
 IsReadOnly = true 
 MaxLength = 200 
 MinLength = 5 
 PendingValue = null 
DCIM_BIOSString 
 AttributeName = UserLcdStr 
 CurrentValue = null 
 DefaultValue = null 
 FQDD = BIOS.Setup.1-1 
 InstanceID = BIOS.Setup.1-1:UserLcdStr 
 IsReadOnly = false 
 MaxLength = 62 
 MinLength = 0 
 PendingValue = null 
DCIM_BIOSString 
 AttributeName = AssetTag 
 CurrentValue = null 
 DefaultValue = null 
 FQDD = BIOS.Setup.1-1 
 InstanceID = BIOS.Setup.1-1:AssetTag 
 IsReadOnly = false 
 MaxLength = 10 
 MinLength = 0 
 PendingValue = null 
. 
. 
. 
17.7  Applying the Pending Values for BIOS & Boot-CreateTargetedConfigJob() 
This method is called to apply the pending values created by the SetAttribute(), SetAttributes(), 
ChangeBootOrderByInstanceID(), and ChangeBootSourceState() methods.  The system will 
automatically reboot depending on the ScheduledStartTime selected. Using the 
CreateTargetedConfigJob() jobID output with the job control section can be used to obtain its status.   
Invoke CreateTargetedConfigJob() with the following parameters and syntax: 
TARGET: This Parameter is the FQDD of the BIOSAttribute instances, obtained from the 
InstanceID field in Section 17.1 
RebootJobType: There are three options for rebooting the system.  
1 = PowerCycle 