White Papers
Dell™ Lifecycle Controller 2 Web Services Interface Guide for Linux  Version: 2.1.0 
167 
 <n1:IsReadOnly>true</n1:IsReadOnly> 
 <n1:LowerBound>0</n1:LowerBound> 
 <n1:PendingValue/> 
 <n1:UpperBound>0</n1:UpperBound> 
</n1:DCIM_RAIDInteger> 
<n1:DCIM_RAIDInteger> 
 <n1:AttributeName>RAIDrebuildRate</n1:AttributeName> 
 <n1:CurrentValue>11</n1:CurrentValue> 
 <n1:FQDD>RAID.Integrated.1-1</n1:FQDD> 
 <n1:InstanceID>RAID.Integrated.1-1:RAIDrebuildRate 
 </n1:InstanceID> 
  <n1:IsReadOnly>false</n1:IsReadOnly> 
 <n1:LowerBound>1</n1:LowerBound> 
 <n1:PendingValue/> 
 <n1:UpperBound>100 
 </n1:UpperBound> 
</n1:DCIM_RAIDInteger> 
<n1:DCIM_RAIDInteger> 
 <n1:AttributeName>RAIDccRate 
 </n1:AttributeName> 
 <n1:CurrentValue>22</n1:CurrentValue> 
 <n1:FQDD>RAID.Integrated.1-1</n1:FQDD> 
 <n1:InstanceID>RAID.Integrated.1-1:RAIDccRate</n1:InstanceID> 
 <n1:IsReadOnly>false</n1:IsReadOnly> 
 <n1:LowerBound>1</n1:LowerBound> 
 <n1:PendingValue/> 
 <n1:UpperBound>100</n1:UpperBound> 
</n1:DCIM_RAIDInteger> 
<n1:DCIM_RAIDInteger> 
 <n1:AttributeName> 
 RAIDreconstructRate 
 </n1:AttributeName> 
 <n1:CurrentValue>33 
 </n1:CurrentValue> 
 <n1:FQDD>RAID.Integrated.1-1 
 </n1:FQDD> 
 <n1:InstanceID>RAID.Integrated.1-1:RAIDreconstructRate 
 </n1:InstanceID> 
 <n1:IsReadOnly>false</n1:IsReadOnly> 
 <n1:LowerBound>1</n1:LowerBound> 
The ‘get’ instance method in 
Section 16.4 used this 
InstanceID as input. 
The ‘set attribute’ method in 
Section 16.19.3 uses the FQDD, 
AttributeName, and a value equal to 
or between the LowerBound and 
UpperBound fields as input.  
The ‘set attributes’ method in 
section 16.19.4 uses the FQDD, 
AttributeName, and a value equal to 
or between the LowerBound and 
UpperBound fields as input.  