Release Notes
Issue 5
Description
When enumeration is performed on multiple devices such as NICs, CNAs, and controllers, the data returned is more than the
maximum envelope size.
Resolution
Increase the envelope size of the client. The recommended envelope size is 1024 kilobytes.
Versions Affected
Lifecycle Controller version 1.6.0
Issue 6
Description
After running several update jobs, some jobs are not executed in some systems.
Resolution
When using WSMAN command to initiate update jobs, make sure to wait for few seconds before submitting the second job.
Versions Affected
Lifecycle Controller version 1.6.0
Issue 7
Description
The Import operation is attempted on SAS controller and an error is reported, if the import is not possible due to the
reasons such as unsupported RAID levels. The controller allows creation of the global hot spares even if there are no VDs and
removes them after systems reboots, and this is an expected behavior of the controller and does not affect the functionality.
Resolution
There is no workaround as it works as designed.
Versions Affected
Lifecycle Controller version 1.6.0
Limitations
None for this release.