• Fully Qualified Device Descriptor (FQDD) of the controller.
• Encryption Mode — Local Key Encryption.
•Key ID.
• Passphrase — A valid passphrase contains 8 to 32 characters. It must
include a combination of uppercase and lowercase letters, numbers,
symbols, and without spaces.
Assigning the Hot Spare
7
Use the FQDD of the physical disk and related virtual disks that is used as
the spare and invoke the
AssignSpare()
method.
Creating the Job
8
Construct the input parameters (for example, Target, RebootType,
ScheduledStartTime, and so on), and use the correct Fully Qualified
Device Descriptor (FQDD) of the controller for Target.
NOTE: See the RAID Profile document at
delltechcenter.com/page/DCIM.Library to see the list of all the supported
input parameters.
9
Invoke the
CreateTargetedConfigJob()
method to apply the pending
values. If this method is successful, the system must return a job ID for the
configuration task you created.
NOTE: The system must reboot to execute the task of setting the attribute or
attributes.
RAID Setup–Post Configuration Scenario
10
Get the job status using the job ID generated earlier.
NOTE: Depending on the network, run the get job status command multiple
times until it shows correct job status. Normally it takes up to 30 seconds.
11
To check if the RAID configuration and the local key application on the
controller are successful, you must verify if the system automatically boots
into USC-LCE and the correct number of SSIB tasks are executed without
any problems.
12
Get the job status using the job ID generated earlier for which this status
message is returned
Job completed successfully
.
13
Repeat step 1 and step 2 and verify if the changes are allied.