User's Manual
80 Frequently Asked Questions
22
What happens when the DeleteJobQueue() method is invoked with a
JobID of JID_CLEARALL from the WSMAN client?
All jobs are cleared. Some services and processes on the iDARC are
restarted and there is a delay of one to three minutes before Remote
Enablement WSMAN commands are available again.
23
When do we see the changes reflected through the WS-Management if
the changes are made locally in HII?
After exiting from USC, the WS-Management interface updates the
available information in approximately 2 minutes.
24
What should be state of the system for the CreateTargetedConfigJob()
method invocation to be successful?
The System must either be powered off, or past BIOS POST (for example,
BIOS or UEFI boot manager), or must have booted into the OS for the
CreateTargetedConfigJob()
method to be successful.
25
What is different about the ProcCore setting for Quad core processors?
For quad port processors, setting the attribute ProcCore value to 4 sets the
current value to "All".
26
Why are the NIC Blink LED attributes always set to NULL after the job
is completed?
A blink LED NIC attribute is a one time setting that you are able to set,
but once SSIB task is complete, it will set the current value back to null.
The purpose of this attribute is to blink the NIC LEDs for a certain
amount of time (seconds).
27
How many attributes can I set through the SetAttribute() method.
You can set only one attribute through the
SetAttribute()
method. To set
two or more attributes in one method invocation, use the
SetAttributes()
method on the services for the component being configured.
RemoteServices1_4.book Page 80 Thursday, October 21, 2010 5:05 PM