User's Manual
38 Remote Services Operations
• Part replacement is supported on modular systems with the following
Broadcom and Intel devices:
• Broadcom NetXExtreme II 5709 Quad Port Ethernet Mezzanine Card
for M-Series
• Broadcom NetXtreme II 57711 Dual Port 10 Gb Ethernet Mezzanine
Card with TOE and iSCSI Offload for M-Series
• Broadcom 57710 10 Gb Ethernet card
• Intel Ethernet X520 10 GBE Dual Port KX4-KR Mezz
For more information on the supported cards, see
Dell Lifecycle Controller
USC/USC-LCE 1.4 User’s Guide
.
Validating vFlash presence Using WS-Management
To ensure that the system is equipped with a Dell-licensed vFlash card follow
these steps:
1
Using an application, script or command line shell that can process WS-
Management based web services requests, send a get instance request for
the DCIM_LCEnumeration class instance with the InstanceID of
"DCIM_LCEnumeration:CCR1".
2
If the vFlash is present, the output will have the following attribute values:
• AttributeName = Licensed
• CurrentValue = Yes
3
If the vFlash is not present on the system, or if it is not Dell-licensed, the
output will have the following attribute values:
• AttributeName = Licensed
• CurrentValue = No
Using WS-Management to get/set Part Firmware and Configuration Update
Attributes
To get the current Part Firmware Update and Collect System Inventory On
Restart property values using WS-Management, an enumerate command
request may be sent to get instances of the class DCIM_LCEnumeration. A
DCIM_LCEnumeration instance object is returned per attribute where the
AttributeName string property on the object will contain the name of the Part
Replacement related property, such as Part Firmware Update. The
RemoteServices1_4.book Page 38 Thursday, October 21, 2010 5:05 PM