another firmware update.
Note: When configuring the FTP server for your repository in the platform update,
you may get a message that indicates that a network connection exists with your
FTP server; however, it may mean that the validation process needs some extra
time depending on your network setting. Click OK on the message box, and try
one more time to connect to the FTP server.
Note: Account access can be disabled only if there is more than
one user enabled on the iDRAC. To enable users, access the iDRAC
Web-based GUI. Navigate to the Users section under the Network/Security
tab and enable users as needed.
Note that at least one more user needs to be enabled in order
to disable the account access in the USC.
Note: In the iDRAC Configuration Wizard, the DNS Domain Name may
contain a maximum of 64 ASCII characters. (282986)
Note: When attempting a Platform Rollback, there may be a two minute delay
before Rollback tasks are displayed on the screen. (287021)
When using Hardware Configuration Advanced Configuration, if you
click on any NIC or BIOS devices and then leave the page and come back,
you may experience delays of up to 18 seconds on all the pages. (286799)
Note: In the iDRAC Configuration Wizard, there is not a selection for
auto-attached on the Virtual Media Config page. (287428)
Note: Intel NIC cards are not supported in the "Platform Update"
option in USC.
During an UEFI based SLES 10 and SLES 11 installation, ensure that
no additional USB or block storage devices are connected to the system.
If there are one, or more USB or block storage devices plugged into the
system, the auto loading of drivers from the embedded storage fails.
This fails because the current implementation of SLES installer reads
only from one USB or block storage device.
If a Non-Dell SD card is attached to the system, the values shown
for "Health" and "Available Space" options are not applicable.
An "Invalid Update Package" error message is displayed, when
- the folder containing the DUP is not accessible.
- the DUP is not present on the USB mass storage device.
- name of the DUP is incorrect.
For an attached Broadcom NetXtreme II 10 Gigabit Ethernet card,
when you change the settings (from the Device Configuration menu)
from "Forced SF" to "MF Allowed", USC displays an error message
"An error occurred. One or more settings may not be restored."
If you click OK, the system reboots.
On McCave systems, the 'Node Interleaving' option on the 'Memory Settings'
page is grayed-out when you access it after a reboot. You must click