White Papers
Dell™ Lifecycle Controller 2 Web Services Interface Guide for Windows Version: 2.1.0
36
DCIM_LifecycleJob
InstanceID = JID_001276741956
JobStartTime = TIME_NA
JobStatus = Downloaded
JobUntilTime = TIME_NA
Message = Package successfully downloaded.
MessageArguments = null
MessageID = RED002
Name = Rollback:DCIM:AVAILABLE:NONPCI:159:2.1.4
Job status after invoking SetupJobQueue
DCIM_LifecycleJob
InstanceID = JID_001276741956
JobStartTime = 00000101000000
JobStatus = Scheduled
JobUntilTime = 20100730121500
Message = Task successfully scheduled
MessageArguments = null
MessageID = JCP001
Name = Rollback:DCIM:AVAILABLE:NONPCI:159:2.1.4
Job status following reboot / install of operation
DCIM_LifecycleJob
InstanceID = JID_001276741956
JobStartTime = 00000101000000
JobStatus = Completed
JobUntilTime = 20100730121500
Message = Job finished successfully
MessageArguments = null
MessageID = USC1
Name = Rollback:DCIM:AVAILABLE:NONPCI:159:2.1.4
7.3 BIOS Firmware “Rollback”
The InstallFromSoftwareIdentity() method is used for installation of a previous version of a component
firmware that is available on the Lifecycle Controller (i.e. “rollback” of component firmware).
All steps to complete a rollback successfully are listed below.
Invoke InstallFromSoftwareIdentity() with the following parameters and syntax:
[InstanceID]: This is the instanceID of the SoftwareIdentify that is to be used to rollback the
firmware to a previous version. The InstanceID can have value such as:
DCIM:AVAILABLE:NONPCI:159:2.1.4
It is available firmware on a NONPCI device.