Administrator Guide

Upgrading SCCM 2007 /CongMgr 2012 SP1
clients with CongMgr 2012 R2 clients on older
Dell Wyse WES7 builds
If you are planning to upgrade the older Dell Wyse WES7 builds that has SCCM 2007/ CongMgr 2012 SP1 Clients with CongMgr 2012 R2
clients, do the following:
1 Log in as an Administrator and disable FBWF.
2 Uninstall the Windows Embedded Device Manager client from Programs and features.
3 Uninstall SCCM 2007/CongMgr 2012 SP1 client using CCM setup /uninstall command.
4 Install the CongMgr 2012 R2 client.
5 Add the following FBWF exclusion list either from the Wyse FBWF tray utility or FBWFMgr.exe command line:
The following exclusions should be added in FBWF enabled state:
\Windows\SMSCFG.ini
\Windows\CCM\wedmtrace.log
\Windows\CCM\clientstate.dat
\Regfdata
\Windows\CCM\InventoryStore.sdf
\Windows\CCM\StateMessageStore.sdf
\Windows\CCM\CcmStore.sdf
\Windows\CCM\ServiceData
6 Reboot the device, and disable FBWF.
7 Merge the following registry:
[HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\RegFilter\Parameters\MonitoredKeys\3]
"ClassKey"="HKLM" "FileNameForSaving"="ConfigMgr.rgf" "RelativeKeyName"="SOFTWARE\\Microsoft\
\CCM\\StateSystem"
8 Get the latest CongMgr 2012 R2 supported scripts from Dell Wyse.
9 Copy the les present in Dell Wyse provided CongMgr 2012 R2 scripts to the following location on your thin client: C:\windows\setup
folder. Overwrite the les when it is prompted.
10 Enable the le based write lter.
11 Follow this entire document.
For more information on client deployment through conguration Manager, refer to technet.microsoft.com/en-us/library/gg682132.aspx.
8
Upgrading SCCM 2007 /CongMgr 2012 SP1 clients with CongMgr 2012 R2 clients on older Dell Wyse WES7
builds
17