Administrator Guide
• Click Apply.
l Select Install Operating System - Apply Data Image 1. In the Options tab select Disable this Step, and then click Apply.
NOTE: This step is not applicable for GPT-based images.
m Select Install Operating System - Apply Windows Settings and ensure that Product Key is blank, ensure that Enable the
Account and specify the local administrator password is selected, and then provide the password as DellCCCvdi.
n Select Install Operating System - Apply Device Drivers. In the Options tab, select Disable this step, and then click Apply.
o Select Setup Operating System - Enable Bitlocker. In the Options tab, select Disable this step, and then click Apply.
p Select OK to close the Task Sequence Editor window for the task sequence.
5 Deploy Disable Write Filter program
a Deploy the Disable Write Filter program created in "Step 3: Create a Software Package and Program that Disables the Write
Filter”. In the User Experience settings of the Deploy Software Wizard, clear the box named Commit changes at deadline or
during a maintenance window (requires restarts).
See www.technet.microsoft.com/en-us/library/gg682178.aspx
b After the task sequence is complete, the thin client reboots and the write-lter is disabled.
NOTE: Time for the Advertisement to appear at the client side depends on the machine and user policy
refresh interval time, and server and network parameters such as server capacity to handle the clients and
network trac.
If you do not receive an Advertisement, then you must initiate on the thin client:
a
Go to Control Panel > Conguration Manager > Actions tab, select Machine Policy Retrieval & Evaluation Cycle, and then
click Initiate Action.
b Go to Control Panel > Conguration Manager > Actions tab, select User Policy Retrieval & Evaluation Cycle, and then click
Initiate Action.
c After successful deployment of the Disable Write Filter program, proceed to the next step.
6 Deploy the Push WES7 Image Task Sequence for Image Push
a Deploy the Push WES7 Image Task sequence created in " Step 4: Create a Push WES7 Image Task Sequence for Image Push". In
the User Experience settings of the deploy Software Wizard, clear / uncheck the box named Commit changes at deadline or
during a maintenance window (requires restart). For more information, see www.technet.microsoft.com/en-us/library/
gg682178.aspx
.
b Once the Task Sequence runs/completes, the thin client restarts in WINPE and deploy the WES7 reference image.
NOTE
: Ensure that the boot order in the BIOS is HDD followed by PXE LAN.
c After successful deployment, the thin client will automatically log on using the local user account named Administrator and the
Dell Wyse scripts will run on the destination thin client. Finally scripts enable the File-Based Write Filter and reboot the thin client.
The destination client is now ready for use.
Imaging Wyse thin clients with
Conguration Manager 13