Release Notes
NOTE: For Dell Compellent SAN, the HBAnyware CLI or OneCommand Manager also must be installed on the remote
Windows, Linux, and VMware host to successfully collect Emulex FC HBA collection.
NOTE: For Broadcom 57810 CNA Collection, BASP BACS Management Application must be installed on the remote
Windows host.
NOTE: For Brocade Collection, Brocade Command Line Utility(BCU) must be installed on the remote Windows host.
● To collect from EMC, use a system that is not a Fibre Channel attached host.
● To collect from EqualLogic, install Lasso on one of the iSCSI hosts.
● For ESX/ESXi, the normal or sudo user should have PasswordAuthentication or Keyboard interactive authentication enabled.
● For ESX/ESXi, the root user should have permitrootlogin enabled and the PasswordAuthentication or Keyboard interactive
authentication should be enabled.
● For PowerVault MD Series devices, MD Storage Manager software should be installed in the system running Lasso.
● For SAN HQ devices, Dell EqualLogic SAN Headquarters Server version should be installed in the windows host.
● For PowerConnect Controller, ensure that the following ports are enabled and are accessible on the controller:
SSH: Port 22
Telnet: Port 23
SNMP: Port 161
To enable SNMP, in a browser, enter the <Controller IP Address> to connect to the controller. In the Mobility Controller
page, go to Configuration > SNMP and add the SNMP community string.
NOTE: The community string is case-sensitive.
● For System Center Virtual Machine Manager (SCVMM), PowerShell must be enabled in target Windows VMM host.
● For Broadcom 57800, 57810 and 57840 CNA collection, Broadcom Advanced Server Program (BASP), Broadcom Advanced
Control Suite (BACS) management application should be installed on the remote windows host.
NOTE: For Brocade collection, Brocade Command Line Utility (BCU) must be installed on the remote windows host.
● For QLogic BCM5700, BCM57810, and BCM57840 collection, QLogic Control Suite must be installed on the remote windows
host.
● For Brocade BR-1010 and BR-1020, Brocade Command Line Utility (BCU) must be installed on the remote windows host.
● For QLogic rebranded Brocade BR-1010 and BR-1020 cards, the appropriate utility is available on the QLogic site.
● For VRTX and FX2, to collect the integrated server information, Lasso should be run as an administrator.
● For FluidFS 7600, ensure that FTP is enabled and you must provide the CLI credential information for FluidFS NAS version
3.0 collection or validation.
● For importing data from the excel sheet, use the Sample_DeviceConfig_Data.xltx file from C:\Program Files (x86)\Dell
\Lasso.
● Lasso MS should have connectivity to remote Dell FTP site (ftp.dell.com) direct or through proxy.
Known Issues
Issue 1
Description: The NX4 configuration is not sent if you run a collection for NX4 without root credentials and the “send full
collection” option is cleared.
Resolution: Make sure that the "send full collection" option is selected before running a collection for NX4 without root
credentials.
Versions/Systems Affected: None.
Issue 2
DescriptionIf an earlier version of Lasso is installed in a folder other than the default version, the customer configuration file is
not moved to the USERPROFILE\Dell\Lasso folder.
Resolution: Move the customer configuration file or use "Load a configuration file" option from Lasso Welcome page to use an
existing customer configuration file.
Versions/Systems Affected: None.
8