Release Notes
NOTE: This timeout mechanism is applicable to all the devices. For collection to be successful, change or update the
corresponding device properties file.
● SANsurfer CLI (FC) must be installed on the remote Windows, Linux, and VMware Host to gather FC HBA information.
● SANsurfer CLI (iSCSI) must be installed on the remote Windows, Linux, and VMware hosts to gather iSCSI HBA information.
● HBAnyware CLI (FC) or OneCommand Manager must be installed on the remote Windows, Linux, and VMware hosts to
gather FC HBA information.
What Is New In This Release
● Discovery and collection from the integrated servers of a Dell PowerEdge M1000e chassis.
● New device support:
○ Dell Networking C9000 and C9010
○ Dell Networking C1048P port extender (PE)
○ QLogic 578xx CNA cards (previously Broadcom CNA cards)
○ Dell NAS devices with Fluid File System (FluidFS) version 5.0
○ Dell Networking Force10 switches firmware version 9.9 and 9.10
○ Dell Networking switches firmware version 6.2.7
○ EqualLogic firmware version 8.0
○ Dell Compellent SC70x0 series
● Additional operating systems support:
○ Red Hat Enterprise Linux 6.8 and 7.2
○ SUSE Linux Enterprise Server 12 SP1
○ Citrix XenServer 7.0
○ VMware ESXi 6.0 U1
● Enhancements:
○ Fault Domain information for the I/O cards on Dell Compellent storage arrays
○ Spanning Tree PortFast attribute from PowerConnect and Dell Networking switches
○ FCHP onboard settings and other sections for Windows, Linux, and VMware ESXi 6.0 and 5.5
○ Brocade Fibre Channel switch interconnect fabric
○ Virtual port information for iSCSI and Fibre Channel I/O cards on Dell Compellent storage arrays
○ Integration of Dell System E-Support Tool (DSET) version 3.7
○ Ability to configure the Lasso web server IP address from lasso GUI for Dell Compellent storage arrays
○ Ability to parse the Ethernet ports of MD Series storage array controllers
Fixes
The following problems were reported in earlier releases of Lasso and are corrected in this release:
● LASSO-4022 Lasso collects SC8000 without any errors, but report only contains contact data.
● LASSO-3893 CMC version 2.10 onwards PCI slot information is not parsing.
● LASSO-3888 MD-Array: Lasso is not showing Ethernet 1 Network Port information under Controller section.
● LASSO-3825 Lasso is not showing proper Linux host iSCSI and non-iSCSI data.
Important Points
● Ensure that IP connectivity is available to all defined devices.
● .NET framework 2.0 and SP v1.0 or later.
NOTE:
For EqualLogic, MD series, and Dell Compellent SAN, .Net framework 2.0 or later must be installed on the
remote Windows host to successfully collect data.
NOTE: For EqualLogic, Dell Compellent, and MD series SAN, the SANsurfer CLI (iSCSI) software must be installed on
the remote Windows, Linux, and VMware hosts to successfully collect iSCSI HBA information.
NOTE: For Dell Compellent SAN, the SANsurfer CLI (FC) must be installed on the remote Windows, Linux, and VMware
host to successfully collect Qlogic FC HBA collection.