Release Notes
○ iDRAC
○ Windows
○ Linux
○ VMware
● Management and Monitoring Software:
○ HIT kit For VMware
○ SAN HQ
○ VCenter 5.0 and 5.1
○ SCVMM 2008 and 2012 (excluding Win2K12R2)
● Wireless Controllers:
○ Dell Networking W-Series Mobility Controllers W-7210/W-7220/W-7240/W-3200/W-3400/W-3600/W-650/W-651/
W-6000/W-620
Before collecting data, ensure to perform the settings provided in Software Requirements section.
Supported Web Browsers
Lasso supports the following web browsers:
● Internet Explorer 8.0 and later
NOTE: For Internet Explorer, enable scripting in Internet Options or include http://127.0.0.1 as a Trusted Site.
● Mozilla Firefox 12.0, 11.0, and 10.0 for Windows Server 2008 Professional and Microsoft Windows Small Business Server
2011.
● VRTX, FX2, and M1000e integrated server report should be viewed with Internet Explorer 8.0 and later.
Software Requirements
● Windows Systems:
Edit the registry on the remote host using the Windows 2008 Configuration registry script provided in the help file.
○ Edit the registry on the remote host using the Windows 2008 Configuration registry script provided in the help file.
○ Under HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Policies\system\key, add DWORD
value 'LocalAccountTokenFilterPolicy'and set the value data to 1 and reboot the system.
○ Ensure that adequate disk space is available to temporarily store all event logs and other system data.
● UNIX systems:
For more information about Linux, Solaris, HP-UX, and IBM AIX systems, see the readme file available at ftp://
ftp.emc.com/pub/emcgrab/Unix.
For more information about ESX and ESXi, see the readme file available at ftp://ftp.emc.com/pub/emcgrab/ESX/.
NOTE:
Ensure that SSH is installed and configured. Credential for normal user is required to establish SSH session, and
root password is required to run commands as root.
NOTE: Ensure that adequate disk space is available to store a copy of all logs and system data that is collected.
● Fibre Channel Switches:
Enable Telnet on all McData switches for Lasso to collect from them.
● Ethernet Switches:
Enable Telnet on all Ethernet switches.
● Command-line JRE Version 1.6 or later.
● Modular Disk Storage Manager must be installed on the management station for successful MD Series collection.
● The default timeout value is 30 minutes for NX3500 and EqualLogic FS7500 devices. Modify the default timeout value only if
the collection fails for PowerVault NX3500 and EqualLogic FS7500 devices. The timeout value (nas.timeout.value) must be
modified in the NAS.properties file available in the Lasso installation directory.
NOTE: The timeout value is in milliseconds.
6










