Release Notes
Issue 11
Description: Lasso will not parse complete switch port information on which NPIV (Node Port ID Virtualization) is configured
for FC switches.
Resolution: The switch port information is available in the collection text file under the "nsshow -r" command.
Versions/Systems Affected: Lasso Version 4.4 and later.
Issue 12
Description: Lasso collection may run out of space on an ESXi server installed on the SD Card.
Resolution: Required 60 MB to 100 MB of space in /tmp folder of the host.
Versions/Systems Affected: Lasso Version 4.7 and later.
Issue 13
Description: Lasso collection will not fail and "Collection Successful" message is displayed in Lasso GUI for SAN HQ collection if
there are no EqualLogic devices added to SANHQ.
Resolution: EqualLogic devices must be added to the SANHQ software.
Versions/Systems Affected: Lasso Version 4.4 and later.
Issue 14
Description: Lasso collection fails to parse QLogic FC HBA "Device ID" information in some Linux host.
Resolution: None.
Versions/Systems Affected: Lasso Version 4.6 and later.
Issue 15
Description: Lasso validation is unsuccessful on PowerConnect 28xx series switches if switch type is selected as AutoDetect
and Dell Networking.
Resolution: Select switch type as PowerConnect and continue with validation and collection.
Versions/Systems Affected: Lasso Version 4.6 and later.
Issue 16
Description: Collection fails if the PowerConnect switch name contains “MGMT” (for example, MGMTSW1).
Resolution: Avoid using the word MGMT as part of switch name.
Limitations
Issue 1
Description: DF521933: When multiple collections run on an ESXi 5.0 host, Lasso fails to delete the Dell Collector folder from
the temporary directory.
Resolution: None.
Versions/Systems Affected: None.
Issue 2
Description: DF378248: Microsoft Security Essentials detects Lasso as a threat during Windows collection.
Resolution: Disable Microsoft Security Essentials during Windows Collection.
Versions/Systems Affected: None.
10